Product Specifications & Comparative Analysis
Technical Parameters
| Parameter | Specification | Competitor A | Competitor B |
|---|---|---|---|
| CAS Number | 18851-33-7 | 18851-33-7 | 18851-33-7 |
| Purity | ≥99.5% | ≥98% | ≥97.5% |
| Molecular Formula | C₁₂H₉ClN₂·H₂O | C₁₂H₉ClN₂·H₂O | C₁₂H₉ClN₂·H₂O |
| Appearance | White crystalline powder | Off-white powder | Yellow-tinged crystals |
| Solubility | 50 mg/mL in H₂O | 40 mg/mL | 35 mg/mL |
Industrial Applications & Functional Uses
Core Application Areas
- Analytical Chemistry: Metallochromic indicator for transition metal detection
- Pharmaceuticals: Intermediate in antiviral drug synthesis
- Material Science: Chelating agent for luminescent materials
- Environmental Testing: Heavy metal detection in wastewater
- Electroplating: Additive for zinc-nickel alloy plating
Operational Protocols & Safety Measures
Recommended Handling Procedures
- Storage Conditions: Maintain at 2-8°C in airtight container
- Working Concentration: 0.1-10 mM solutions in deionized water
- pH Range: Optimal performance between pH 3.5-6.8
- Molar Extinction Coefficient: ε₂68 = 6,700 L·mol⁻¹·cm⁻¹
Critical Safety Notes
- PPE Requirements: Nitrile gloves + safety goggles
- Incompatibilities: Strong oxidizers, concentrated acids
- Disposal Methods: Neutralize with sodium bicarbonate
Documented Implementation Cases
Case 1: Pharmaceutical Quality Control
Client: European Pharma Manufacturer
Challenge: Trace cadmium detection in vaccine adjuvants
Solution: Implemented colorimetric assay with 0.05% detection limit
Outcome: Achieved 99.8% compliance with EMA standards
Case 2: Mining Environmental Remediation
Client: Chilean Copper Miner
Challenge: Real-time copper ion monitoring
Solution: Developed continuous flow analysis system
Result: Reduced wastewater treatment costs by 40%
Verified User Experiences
Testimonial 1: Analytical Lab Director
“The batch-to-batch consistency exceeded our ICP-MS calibration requirements, demonstrating superior performance compared to three alternative suppliers we tested.”
Testimonial 2: Materials Research Team
“Achieved 15% improvement in luminescent quantum yield through optimized chelation protocols using this product.”
Technical Support & Ordering Information
Contact Our Experts
For bulk pricing, SDS documentation, or application assistance:
Email: info@vivalr.com
Phone: (86) 15866781826
Request Custom Formulation
Specify your requirements:
– Preferred purity grade (98-99.9%)
– Packaging specifications (1g-25kg)
– GMP certification needs



评论
目前还没有评论。